Internally threaded wedge anchor for simple hammer-set installation

Features and benefits

  • High performance in cracked and non-cracked concrete confirmed by ETA
  • Product is covered with European Technical Assessment for multi-point non-structural fixings
  • Product recommended for applications requiring fire resistance
  • Internally threaded to be used with threaded stud or bolt
  • Easy to install by hammer action and manual setting tool
  • Slotted sleeve and internal wedge component together facilitate easy setting and expansion
  • Product was tested for construction fixing

Product information

Size

Product Code

Anchor

Fixture

Diameter

External diameter

Length

Internal thread length

Hole diameter

d

dnom

L

lg

df

[mm]

[mm]

[mm]

[mm]

[mm]

M6

R-DCA-06-25

6

8

25

11

7

R-DCA-06-25-100B

6

8

25

11

7

M8

R-DCA-08-30

8

10

30

14

9

R-DCA-08-30-100B

8

10

30

14

9

M10

R-DCA-10-40

10

12

40

19

12

R-DCA-10-40-50B

10

12

40

19

12

M12

R-DCA-12-50

12

15

50

25

14

R-DCA-12-50-30B

12

15

50

25

14

M16

R-DCA-16-65

16

20

65

28

18

R-DCA-16-65-15B

16

20

65

28

18

M20

R-DCA-20-80

20

25

80

38

22

Base material

  • Cracked concrete C20/25-C50/60

    Cracked concrete C20/25-C50/60

  • Non-cracked concrete C20/25-C50/60

    Non-cracked concrete C20/25-C50/60

  • Unreinforced concrete

    Unreinforced concrete

  • Reinforced concrete

    Reinforced concrete

Applications

  • Pipelines systems
  • Ventilation systems
  • Sprinkler systems
  • Cable conduits and wires
  • Gratings

Installation guide

Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
  1. Drill a hole of required diameter and depth
  2. Clear the hole of drilling dust and debris (using blowpump or equivalent method)
  3. Insert wedge anchor, slotted end first
  4. Use the setting tool to drive the internal wedge into the anchor
  5. Insert bolt or stud through fixture and tighten to the recommended torque

Installation data

Normal concrete

Size

M6

M8

M10

M12

M16

M20

Thread diameter

d

[mm]

6

8

10

12

16

20

Hole diameter in substrate

d0

[mm]

8

10

12

15

20

25

Max. installation torque

Tinst

[Nm]

4.5

11

22

38

98

130

Min. hole depth in substrate

h0

[mm]

27

32

42

52

67

82

Min. installation depth

hnom

[mm]

25

30

40

50

65

80

Min. substrate thickness

hmin

[mm]

80

80

80

100

130

160

Min. spacing

smin

[mm]

200

200

200

200

260

320

Min. edge distance

cmin

[mm]

150

150

150

150

195

240

Associated products

  • RT-MAXA Drill bits Aggressor SDS max

    RT-MAXA Drill bits Aggressor SDS max

  • RT-SDSA Drill bits Aggressor SDS plus

    RT-SDSA Drill bits Aggressor SDS plus

  • R-PRH18-XL2 Cordless RawlHammer 18V SDS plus, set

    R-PRH18-XL2 Cordless RawlHammer 18V SDS plus, set

  • RT-SDSR Drill bits Rebardrill SDS plus

    RT-SDSR Drill bits Rebardrill SDS plus

  • R-BLOWPUMP Blow Pump

    R-BLOWPUMP Blow Pump

  • ce
  • iso 9001
  • ISO 4001
  • isots16949
  • ohsas 18001
  • tuv